HazoGuard MC-HL Control 600V Multi-conductor FR-XLP/PVC

Product Construction: Two or more stranded copper conductors (sizes #8 AWG and larger are compact stranded), XLPE insulated, and color-coded conductors, ground wire, Fillers, binder tape over core, aluminum continuously welded and corrugated sheath, PVC jacket overall.
Voltage: 600V
More details…

HazoGuard MC-HL Power 600V 3C & 4C FR-XLP/PVC

Product Construction: Two or more stranded copper conductors (sizes #8 AWG and larger are compact stranded), XLPE insulated, and color-coded conductors, ground wire, Fillers, binder tape over core, aluminum continuously welded and corrugated sheath, PVC jacket overall.
Voltage: 600V
More details…

HazoGuard MC-HL Instrumentation Cable (Pairs/Triads) 600V POS-SPOS-STOS

Conductor: Bare soft annealed copper, Class B, 7-strand concentric per ASTM B-8.
Insulation: Flame-retardant (PVC) per UL 83
Jacket: Nylon per UL 83
Inner Jacket: Black, flame-retardant (PVC) per UL Standard 1569. A rip cord is laid longitudinally under the jacket to facilitate removal. 
Sheath: Continuously welded and corrugated, aluminum sheath meeting UL 1569. 
Outer Jacket: Black, flame-retardant (PVC) per UL Standard 1569.
Shield: Yes
Voltage: 600V
More details…

Multi-Conductor 600V MC-HL, FR-XLPE

Conductor: Two or more stranded copper conductors, sizes #8 AWG and larger are compact stranded.
Insulation: XLPE-insulated, color-coded conductors.
Color Code: Per ICEA Method 1, Table E-2.
Assembly and Jacket: The individual conductors are cabled together with ground wire(s) and non-hygroscopic fillers and binder tape overall,
continuous corrugated aluminum sheath armor with black PVC jacket.
Conductor Temperature: 90ºC dry or wet
Sizes: #14 AWG – #10 AWG
Voltage: 600V
More details…

3C and 4C 600V MC-HL, FR-XLPE

Conductor: Two or more stranded copper conductors, sizes #8 AWG and larger are compact stranded.
Insulation: XLPE-insulated, color-coded conductors, ground wire (MC-HL only), fillers (as necessary), binder tape over core, corrugated aluminum sheath with PVC jacket overall.
Conductor Temperature: 90ºC dry or wet
Sizes: #14 AWG – 750 kcmil
Voltage: 600V
More details…

MC-HL 5kV 8kV MV-105 3C EPR/PVC

Conductor: Annealed copper per ASTM B3. Compact stranding per ASTM B496.
Insulation: 115 mil Ethylene Propylene Rubber (EPR) insulation per ICEA S-93-639 and UL 1072. Extruded Insulation Shield (EIS): Thermoset semi-conducting polymeric layer, free stripping from the insulation per ICEA S-93-639 and UL 1072. 
Grounding Conductor(s): Three split Class B stranded bare annealed copper ground conductors sized in accordance with UL 1072 and NEC Article 250. 
Armor: Impervious, continuously welded and corrugated aluminum alloy sheath per UL 1072 and 1569. Meets grounding requirements of NEC Article 250.
Jacket: Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), yellow. Low-temperature performance meets ASTM D746 brittleness temperature at or below -40ºC.
Shield: Yes
Voltage: 5kV-8kV
More details…

MC-HL 15kV MV-105 3C EPR/PVC

Conductor: 2 AWG through 750 kcmil bare annealed copper per ASTM B3. Compact stranding per ASTM B496.
Grounding Conductor(s): Class B stranded bare annealed copper ground conductor sized in accordance with UL 1072 and NEC Article 250. 
Armor: Impervious, continuously welded and corrugated aluminum alloy
sheath per UL 1072 and 1569. Meets grounding requirements of NEC Article 250. 
Jacket: Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), red. Low-temperature performance meets ASTM D746 brittleness temperature at or below -40ºC.
Shield: Yes
Voltage: 15kV
More details…

MC 600V Continuous Armor Multi-conductor XLP/PVC

Conductor: Two or more stranded copper conductors, sizes #8 AWG and larger are compact stranded.
Insulation: XLPE-insulated, color-coded conductors.
Color Code: Per ICEA Method 1, Table E-2.
Assembly and Jacket: The individual conductors are cabled together with non-hygroscopic fillers and binder tape overall, continuous corrugated
aluminum sheath armor with black PVC jacket overall.
Conductor Temperature: 90ºC dry or wet
Sizes: #14 AWG – #10 AWG
Voltage: 600V
More details…

23AWG 4Pr. CAT 6E

Conductor: 24 AWG solid bare copper
Dielectric: Solid PE
Assembly: Each pair has different lay length for crosstalk prevention and rip cord added.
Inner Jacket: PVC
Armor: A close-fitting, impervious, continuous, aluminum sheath
Outer Jacket: Blue PVC
Voltage: