Diesel Locomotive
Conductor: Fully annealed, flexible, stranded, tin-coated copper per AAR 589
Insulation: Flame-retardant, cross-linked Ethylene Propylene (EP) with separator tape over the conductor to facilitate stripping
Jacket: Black, flame-retardant, sunlight-, ozone- and oil resistant, lead-free Cross-linked Chlorinated Polyethylene (XL-CPE). Other jacket colors available upon request
Shield: No
Voltage: 600V-2000V
More details…
Type W – Single Conductor
Conductor: Fully annealed, stranded, bare copper
Insulation: Premium-grade 90ºC EPDM
Cable Reinforcement: An open polyester braid reinforcement is applied between the insulation and jacket for mechanical strength.
Jacket: 90ºC, black. Temperature range: -40ºC to +90ºC. Voltage rating: 600V –Type RHH/RHW; 2kV –Type W.
Shield: No
Voltage: 600V
More details…
Type W – 2, 3, 4 & 5 Conductor
Conductor: Fully annealed, stranded, bare copper
Insulation: Premium-grade, color-coded 90ºC EPDM. Jacket: 90ºC, black.
Temperature range: -40ºC to +90ºC
Jacket: No
Shield: No
Voltage: 600V-2000V
More details…
Type G-GC – 3 & 4 Conductor 600V – 2000V
Conductor: Fully annealed, stranded, bare copper
Insulation: Premium-grade, color-coded 90ºC EPDM. Insulated grounds and ground checks.
Shield: No
Jacket: Yes
Voltage: 600V
More details…
Welding Cable
Conductor: Fully annealed, stranded, bare copper, Class K
Insulation: N/A
Jacket: Premium-grade 90ºC EPDM, black or red. Temperature range: -40ºC to +90ºC..
Shield: No
Voltage: 600V
More details…
Type SOOW 18-16 AWG
Conductor: Fully annealed, stranded, bare copper per ASTM B-174.
Insulation: Premium-grade, color-coded 90ºC EPDM. See color chart.
Jacket: Black. Temperature range: -40ºC to +90ºC.
Shield: No
Voltage: 600V
More details…
Type SOOW 14-10 AWG
Conductor: Fully annealed, stranded, bare copper per ASTM B174.
Insulation: Premium-grade, color-coded 90ºC EPDM. See color chart.
Jacket: Black. Temperature range: -40ºC to +90ºC..
Shield: No
Voltage: 600V
More details…
Type SOOW 8-2 AWG
Conductor: Fully annealed, stranded, bare copper per ASTM B174.
Insulation: Premium-grade, color-coded 90ºC EPDM. See color chart.
Jacket: Black. Temperature range: -40ºC to +90ºC
Shield: No
Voltage: 600V
More details…
Stage Lighting
Conductor: Fully annealed, stranded, bare copper per ASTM B172.
Insulation: N/A
Jacket: 105ºC, black. Temperature range: -50ºC to +105ºC.
Shield: No
Voltage: 600V
More details…
Exiter Cable EPR CPE
Conductor: Tinned copper. Separator is rubber-backed fabric tape, helically applied and lapped.xtra-flexible, stranded, bare copper conductor with mylar separator.
Insulation: 0.145" (min. avg.) of ethylene propylene rubber (EPR).
Jacket: : 0.110" (min. avg.) of black, extra-heavy duty chlorinated polyethylene (CPE), surface printed
Shield: No
Voltage: 2000V
More details…